Abstract Extended Abstract Background and Objectives: Given Reconstruction, renovation, and reuse of existing buildings are key strategies for achieving a sustainable built environment. In light of rapid technological advancements, it is essential to assess the condition of existing buildings to ensure they can accommodate the new developments and conditions. Given the technological development, changes in educational methods, and the natural aging of school facilities, many schools across the country now require large-scale renovation. Managing the existing building stock, especially on a large scale, necessitates thoughtful decision-making and planning. Prioritizing buildings for adaptive reuse is a crucial aspect of this approach. Adaptive reuse involves repurposing buildings that have reached the end of their useful life, based on their condition and the needs of the community. This strategy helps create a sustainable built environment by extending the lifespan of existing structures and preserving their structural, social, economic, physical, environmental, and cultural value. This paper aims to provide an effective framework for prioritizing buildings for adaptive reuse and renovation.
Methods: The Adaptive Reuse Potential (ARP) model serves as the primary tool for prioritizing buildings for reuse. This model assesses a building’s potential for adaptive reuse by factoring in its useful life, current age, and predicted physical lifespan. The ARP model generates scores: an ARP score below 20% indicates low reuse potential, a score above 50% indicates high potential, and scores between 20% and 50% indicate moderate potential. The building’s potential for adaptive reuse and the optimal timing for reuse intervention are key criteria for prioritizing school renovations. Schools with higher adaptive reuse potential are prioritized for renovation, and those with less remaining time until the best reuse intervention point are given higher priority. In this study, eight schools in Gilan province are analyzed as case studies, focusing on schools between 25 to 35 years old, with consideration of their geographical distribution. Some of the necessary data and information about schools were obtained from the Organization for Development, Renovation and Equipping Schools of Gilan Province and some through field visits and interviews with the school principals.
Findings: According to the results, the maximum ARP score among the case studies is 78%, the minimum is 49%, and the average is 63%. This indicates that, overall, the case studies show a high potential for adaptive reuse. Building obsolescence, defined as the loss of utility and functionality, was significant in the school buildings. The maximum obsolescence rate observed was 0.0121, the minimum was 0.0073, and the average rate of obsolescence across all case studies was 0.0101. This high obsolescence rate contributes to a reduction in the buildings’ useful life. The research shows that the average effective useful life of the school buildings is 50%, which represents the percentage of the predicted lifespan that is actually utilized. This means that, on average, only half of the buildings’ expected life will be realized, with the other half lost. Therefore, these findings highlight the importance of reusing such buildings.
Conclusion: Renovation and adaptive reuse of older buildings are essential strategies for preserving the existing building stock. However, addressing these buildings requires careful decision-making. Prioritizing buildings for adaptive reuse is a key challenge, particularly on a large scale, as each building has a different priority based on its condition and potential. This paper utilizes the Adaptive Reuse Potential (ARP) model, focusing on building reuse potential and the optimal time for reuse intervention as the two main evaluation criteria, to offer a robust decision-making model for prioritizing buildings for adaptive reuse and renovation. Considering both criteria simultaneously allows for a more precise and comprehensive prioritization. In cases where multiple buildings have the same adaptive reuse potential, evaluating the available time until the optimal reuse intervention can enhance prioritization accuracy. Conversely, if several buildings share the same available time, their reuse potential can be reassessed to determine the best reuse ranking.

A regulation for minimum mandatory dimensions of balconies in residential apartments in the city of Rasht from the perspective of spatial usability

A regulation for minimum mandatory dimensions of balconies in residential apartments in the city of Rasht from the perspective of spatial usability

Volume 14, Issue 2, December 2023, Pages 23-38

https://doi.org/10.30475/isau.2023.337572.1906

Mojtaba Pour Ahmadi, Reza Sedighi

Abstract Extended Abstract Background and Objectives: Today, for various reasons, a small and inadequate floor area is often allocated to private semi-open spaces in apartment housing in Iran. This allocation results in a significant reduction in the efficiency of these spaces. Consequently, the potential of the space to accommodate the daily presence and use by the residents is almost lost. The present study aims to specifically address this issue from the perspective of the development control system and to consider the role of building regulations in ensuring the minimum acceptable usability of these spaces.
Methods: In this research, in the first step, 10 international examples of building codes related to the minimum allowable dimensions of residential balconies in some developed countries of the world including England, Ireland, Australia, Singapore, Japan, Dubai, Luxemburg, and the Netherlands are studied and an attempt is made to identify the logic of calculating these values. In the second step, a review of building codes related to the minimum dimensions and floor area of semi-open private spaces in the current development control system of Iran and specifically the city of Rasht is performed. In the following, an attempt is made to provide a definition of the “usable minimal balcony” for the city of Rasht and to calculate its required area and dimensions. In the next step, the current status of balconies design in the apartment housing in Rasht is examined. To do this, the apartment plans approved by the plans control department of the Iran Construction Engineering Organization (IRCEO) of Rasht City were used and we examined all the apartment housing plans of three floors and above, which were approved in this organization in the period of three months from January to March 2021. During this period, 340 apartment units with a total of 401 balconies were approved by the organization. In the final step, an attempt was made to make a comparison between the minimal balcony dimensions defined in the present study and the existing balconies in the statistical community.
Findings: Based To define the minimal usable balcony dimensions, the specific conditions of the target community must be considered. Otherwise, the possibility of enforcing this rule will be reduced. It should be noted that currently in the city of Rasht, there are no regulations regarding the minimum dimensions of these spaces. On the other hand, the current common dimensions of balconies in the housing market of Rasht City are significantly smaller than the standards of the studied countries. This has its own economic, social, and cultural reasons and the study of these issues is outside the scope of the present study. However, it can be concluded that the required dimensions and floor area of the balcony in Rasht apartment housing should be defined as smaller than the countries studied. Based on these considerations, the required dimensions of balconies depend on the number of bedrooms, the number of people living in the residential unit, and, in some cases, the geographical orientation of the balcony in the studied countries. However, in the present study, the minimum dimensions of the balcony in all apartment units are considered a fixed value. Thus, an efficient minimal balcony is considered one that has the necessary area for the installation and proper operation of a small set of a table and chairs for two people, a barbecue, and a gas boiler. Accordingly, the standard is formulated as follows: “In every residential apartment unit, it is necessary to provide a balcony with a minimum clear width of 1.25 meters and a minimum useful floor area of 3.75 square meters.”
Conclusion: Based on the findings of the survey, it can be concluded that, firstly, a small percentage of the current balconies have the required area for proper use by residents. This is due to the small and unsuitable dimensions of these balconies. To be more precise, in one-bedroom residential units, only 16%, in two-bedroom units, 11%, and in three-bedroom units and more, 25% of the balconies can accommodate a table and chairs for two people, a gas boiler, and a barbecue. This finding is in line with the findings of researchers who, based on their qualitative research, have introduced inadequate dimensions of balconies as one of the main reasons for the inefficiency of balconies in apartment housing in Iran today. Secondly, it will have a relatively better perspective for application in the Rasht development control system, if regardless of the number of bedrooms in a residential unit, the minimum standard dimensions and area for balconies is formulated as a minimal two-person balcony. Currently, the proportion of two-bedroom units with a minimal four-person balcony is only 7% of the total (compared to 11% for two-person balconies) and the proportion of three-bedroom units with a minimal six-person balcony is only 11% (compared to 25% for two-person balconies).